Do you have an Ideal boiler that’s misbehaving?

If so, the error code that it’s displaying can help you to identify the likely fault. Your boiler manual should contain a list of the Ideal error codes for your model, or you could simply check out the codes below.

Remember that only Gas Safe engineers are allowed to remove a boiler’s case or any parts, or even unscrew a panel. So, if the error code you see indicates that any of these things need to happen, you’ll need a professional to help you.

For expert advice and guidance relating to your Ideal boiler and its error code, why not jump on a 15-minute video call with one of the experienced professionals at Herofix? You can book a time online at Herofix.com.

Ideal boilers we have covered in this error code list:

List of Ideal Boiler Error Codes

Error CodeSystem Behaviour
C0Boiler chip card (BCC) activation fault
C2Boiler chip card (BCC) fault
F1Low water pressure
F2Flame loss
F3Fan fault
F4Flow thermistor fault
F5Return thermistor fault
F6Outside sensor failure
F7Low mains voltage
F9Unconfigured printed circuit board (PCB)
L1Flow temperature overheat or no water flow
L2Flame loss
L55 boiler resets in 15 minutes
L6False flame lockout

Common Ideal Error Codes

ErrorSystem Behaviour
0The boiler is in standby mode awaiting either a central heating call or hot water demand
CThe boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler
DThe boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler
CThe boiler is operating in central heating mode
dThe boiler is operating in hot water mode
FThe boiler is operating in frost mode

Ideal Boiler Error Descriptions

Error DescriptionCause
Thermal fuse lockoutReset the boiler
Too many boiler resets5 resets within 15 minutes. Turn power off and on.
Printed circuit board (PCB) replaced incorrectlyEnsure the boiler chip card (BCC) is fitted correctly.
Low mains voltageLess than 160V to boiler. Contact electricity provider.
Low water pressureIncrease system pressure to 1.5 bar
Flow/Return reversedCheck if flow thermistor is correctly clipped to pipe. Replace flow thermistor.
Printed circuit board (PCB) replacedReset the boiler
No connection to primary printed circuit board (PCB)Unblock pump
Pump rotor blockedNo connection to primary printed circuit board (PCB)
Flow temperature setpoint cannot be increased to 80ºCEnsure flow temperature is not limited within installer mode
Pump runs during the nightEnsure system frost protection temperature setpoint isn’t set too high
Has the printed circuit board (PCB) just been replaced?Reset the boiler
Are the boiler, central heating and hot water systems filled with water? Are all isolation valves and radiator valves open?Fill and vent the system and open all isolation valves, then reset the boiler
Is the Flow/Return differential across the boiler in excess of 30cCheck the flow and return thermistors
Check that the pump is rotating freely.Replace the pump, then reset the boiler
If the boiler is reset, does it ignite for a short time and then extinguish?Check the detection electrode and associated harness for continuity, visual condition and position. Check if the condensate pipe is blocked.
Is the gas pressure available at the boiler > 18mBarCheck gas supply and rectify fault
Is 215Vdc available at the gas valve during ignition?Check wiring from gas valve to printed circuit board (PCB) and replace if necessary, otherwise replace the main PCB
Unplug the gas valve – is the resistance between the pins between 1kW and 10kW?Replace gas valve

Ideal Logic Max & Logic Plus Regular Boiler Error Codes

Error CodeSystem Behaviour
L1Flow temperature overheat lockout or no water flow lockout
L2Ignition lockout
LC5 restarts within 15 minutes
L6False flame lockout
FAFlow return reversed
FDNo water flow
F2 or FN or LNFlame loss
F3Fan fault
L4 or F4Control / no flow thermistor fault
L5 or F5Return thermistor fault
F6Outside sensor fault
F7Low mains voltage Contact electricity provider
F9, L9, F8 or L8Printed circuit board (PCB) unconfigured or fault
FUDiff greater than 50c check isolation valves are open
No central heatingBook an engineer
No hot waterBook an engineer
No displayBook an engineer

Ideal Logic Max Plus Combi Boiler Error Codes

ErrorSystem Behaviour
Overheat lockoutBleed radiators, refill system to 1.0 bar, check that radiator and boiler valves are open and reset boiler. If fault continues book an engineer.
Ignition lockoutCheck gas appliances work and restart boiler.
Too many restarts5 starts within 15 minutes. Turn power on and off.
Flame on before gas onFalse flame lockout.
Water pressureWith boiler off and system cold fill system to 1.0 bar and bleed radiators if fault continues contact an installed

Ideal Logic Max System/Logic Plus System Boiler Error Codes

ErrorSystem Behaviour
L1Flow temperature overheat lockout or no water flow lockout
L2Ignition lockout
LCTurn power off and on
L6False flame lockout
F1Low water pressure
F2, FN or LNFlame loss
F3Fan fault
L4 or F4Control / no flow thermistor fault
L5 or F5Return thermistor fault
F6Outside sensor fault
F7Low mains voltage – contact electricity provider.
F9, L9, F8 or L8Printed circuit board (PCB) unconfigured or fault
FUDifference greater than 50c – check isolation valves are open
No central heatingBook an engineer
No hot waterBook an engineer
No displayBook an engineer

Ideal Vogue Boiler Error Codes

System FaultBoiler Behaviour
Too many resets5 restarts within 15 minutes
Flame on before gas valve onFlame on before gas valve is on
Flow thermistor faultFlow thermistor error
Low mains voltageLess than 185v to boiler then check voltage at boiler mains in if mains voltage is okay pump needs replacing
Low water pressureLow water pressure
Flow return reversedCheck if the flow thermistor is correctly clipped to pipe. If not, replace flow thermistor.
Printed circuit board (PCB) recently replacedReset boiler
Pump rotor blockedUnblock pump
Flow temperature setpoint cannot be increased to 80cCheck flow and return thermistors securely clamped to pipes check flow and return thermistor
Overheat lockout errorBook an engineer
Ignition lockoutBook an engineer
Flame lossBook an engineer
Thermal fuse lockoutBook an engineer
Outside sensor faultBook an engineer
Return thermistor faultBook an engineer
Fan faultBook an engineer
Printed circuit board (PCB) errorBook an engineer
No central heating but domestic hot water workingBook an engineer
No hot water but central heating workingBook an engineer
No water flow faultBook an engineer
No water flow faultBook an engineer
Toom many resets5 restarts within 15 minutes