Do you have an Ideal boiler that’s misbehaving?
If so, the error code that it’s displaying can help you to identify the likely fault. Your boiler manual should contain a list of the Ideal error codes for your model, or you could simply check out the codes below.
Remember that only Gas Safe engineers are allowed to remove a boiler’s case or any parts, or even unscrew a panel. So, if the error code you see indicates that any of these things need to happen, you’ll need a professional to help you.
For expert advice and guidance relating to your Ideal boiler and its error code, why not jump on a 15-minute video call with one of the experienced professionals at Herofix? You can book a time online at Herofix.com.
Ideal boilers we have covered in this error code list:
- List of Ideal Boiler Error Codes
- Common Ideal Error Codes
- Ideal Boiler Error Descriptions
- Ideal Logic Max & Logic Plus Regular Boiler Error Codes
- Ideal Logic Max Plus Combi Boiler Error Codes
- Ideal Logic Max System/Logic Plus System Boiler Error Codes
- Ideal Vogue Boiler Error Codes
List of Ideal Boiler Error Codes
Error Code | System Behaviour |
---|---|
C0 | Boiler chip card (BCC) activation fault |
C2 | Boiler chip card (BCC) fault |
F1 | Low water pressure |
F2 | Flame loss |
F3 | Fan fault |
F4 | Flow thermistor fault |
F5 | Return thermistor fault |
F6 | Outside sensor failure |
F7 | Low mains voltage |
F9 | Unconfigured printed circuit board (PCB) |
L1 | Flow temperature overheat or no water flow |
L2 | Flame loss |
L5 | 5 boiler resets in 15 minutes |
L6 | False flame lockout |
Common Ideal Error Codes
Error | System Behaviour |
---|---|
0 | The boiler is in standby mode awaiting either a central heating call or hot water demand |
C | The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler |
D | The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler |
C | The boiler is operating in central heating mode |
d | The boiler is operating in hot water mode |
F | The boiler is operating in frost mode |
Ideal Boiler Error Descriptions
Error Description | Cause |
---|---|
Thermal fuse lockout | Reset the boiler |
Too many boiler resets | 5 resets within 15 minutes. Turn power off and on. |
Printed circuit board (PCB) replaced incorrectly | Ensure the boiler chip card (BCC) is fitted correctly. |
Low mains voltage | Less than 160V to boiler. Contact electricity provider. |
Low water pressure | Increase system pressure to 1.5 bar |
Flow/Return reversed | Check if flow thermistor is correctly clipped to pipe. Replace flow thermistor. |
Printed circuit board (PCB) replaced | Reset the boiler |
No connection to primary printed circuit board (PCB) | Unblock pump |
Pump rotor blocked | No connection to primary printed circuit board (PCB) |
Flow temperature setpoint cannot be increased to 80ºC | Ensure flow temperature is not limited within installer mode |
Pump runs during the night | Ensure system frost protection temperature setpoint isn’t set too high |
Has the printed circuit board (PCB) just been replaced? | Reset the boiler |
Are the boiler, central heating and hot water systems filled with water? Are all isolation valves and radiator valves open? | Fill and vent the system and open all isolation valves, then reset the boiler |
Is the Flow/Return differential across the boiler in excess of 30c | Check the flow and return thermistors |
Check that the pump is rotating freely. | Replace the pump, then reset the boiler |
If the boiler is reset, does it ignite for a short time and then extinguish? | Check the detection electrode and associated harness for continuity, visual condition and position. Check if the condensate pipe is blocked. |
Is the gas pressure available at the boiler > 18mBar | Check gas supply and rectify fault |
Is 215Vdc available at the gas valve during ignition? | Check wiring from gas valve to printed circuit board (PCB) and replace if necessary, otherwise replace the main PCB |
Unplug the gas valve – is the resistance between the pins between 1kW and 10kW? | Replace gas valve |
Ideal Logic Max & Logic Plus Regular Boiler Error Codes
Error Code | System Behaviour |
---|---|
L1 | Flow temperature overheat lockout or no water flow lockout |
L2 | Ignition lockout |
LC | 5 restarts within 15 minutes |
L6 | False flame lockout |
FA | Flow return reversed |
FD | No water flow |
F2 or FN or LN | Flame loss |
F3 | Fan fault |
L4 or F4 | Control / no flow thermistor fault |
L5 or F5 | Return thermistor fault |
F6 | Outside sensor fault |
F7 | Low mains voltage Contact electricity provider |
F9, L9, F8 or L8 | Printed circuit board (PCB) unconfigured or fault |
FU | Diff greater than 50c check isolation valves are open |
No central heating | Book an engineer |
No hot water | Book an engineer |
No display | Book an engineer |
Ideal Logic Max Plus Combi Boiler Error Codes
Error | System Behaviour |
---|---|
Overheat lockout | Bleed radiators, refill system to 1.0 bar, check that radiator and boiler valves are open and reset boiler. If fault continues book an engineer. |
Ignition lockout | Check gas appliances work and restart boiler. |
Too many restarts | 5 starts within 15 minutes. Turn power on and off. |
Flame on before gas on | False flame lockout. |
Water pressure | With boiler off and system cold fill system to 1.0 bar and bleed radiators if fault continues contact an installed |
Ideal Logic Max System/Logic Plus System Boiler Error Codes
Error | System Behaviour |
---|---|
L1 | Flow temperature overheat lockout or no water flow lockout |
L2 | Ignition lockout |
LC | Turn power off and on |
L6 | False flame lockout |
F1 | Low water pressure |
F2, FN or LN | Flame loss |
F3 | Fan fault |
L4 or F4 | Control / no flow thermistor fault |
L5 or F5 | Return thermistor fault |
F6 | Outside sensor fault |
F7 | Low mains voltage – contact electricity provider. |
F9, L9, F8 or L8 | Printed circuit board (PCB) unconfigured or fault |
FU | Difference greater than 50c – check isolation valves are open |
No central heating | Book an engineer |
No hot water | Book an engineer |
No display | Book an engineer |
Ideal Vogue Boiler Error Codes
System Fault | Boiler Behaviour |
---|---|
Too many resets | 5 restarts within 15 minutes |
Flame on before gas valve on | Flame on before gas valve is on |
Flow thermistor fault | Flow thermistor error |
Low mains voltage | Less than 185v to boiler then check voltage at boiler mains in if mains voltage is okay pump needs replacing |
Low water pressure | Low water pressure |
Flow return reversed | Check if the flow thermistor is correctly clipped to pipe. If not, replace flow thermistor. |
Printed circuit board (PCB) recently replaced | Reset boiler |
Pump rotor blocked | Unblock pump |
Flow temperature setpoint cannot be increased to 80c | Check flow and return thermistors securely clamped to pipes check flow and return thermistor |
Overheat lockout error | Book an engineer |
Ignition lockout | Book an engineer |
Flame loss | Book an engineer |
Thermal fuse lockout | Book an engineer |
Outside sensor fault | Book an engineer |
Return thermistor fault | Book an engineer |
Fan fault | Book an engineer |
Printed circuit board (PCB) error | Book an engineer |
No central heating but domestic hot water working | Book an engineer |
No hot water but central heating working | Book an engineer |
No water flow fault | Book an engineer |
No water flow fault | Book an engineer |
Toom many resets | 5 restarts within 15 minutes |
If all of this just sounds like gobbledygook, don’t worry – nobody expects you to be an expert on boilers! You can book a 15-minute video call with one of the professional, qualified heating engineers at Herofix.com to help diagnose your error and put a plan in place to fix it.