Do you have a Vaillant boiler error code problem?

Do you have a Vaillant boiler? If so, and if it’s acting up, this list of Vaillant models and their error codes could help you to discover what’s wrong.

Why not have a scan through and see if you can spot your Vaillant error code? If you can’t, you can get in touch at Herofix.com to book a 15-minute video call to diagnose the fault. Even if you can find your code below, our team of professionals is on hand to discuss your boiler and how to repair it.

Before we go any further, there’s one quick warning… You are not permitted to take off a boiler’s case, remove any parts or unscrew any panels unless you are a Gas Safe engineer. Doing so could be immensely dangerous.

Vaillant boilers we have covered in this error code list:

Vaillant EcoMax Pro 18/28E

ErrorPossible Cause
F.1Lack of gas, a fault with the ignition or flue – may need to adjust the gas valve or replace a defective electrode lead.
F.4Ignition fault.
F.5The system has suffered a fault due to overheating.
F.6Your flow NTC has developed a fault.
F.17Check the polarity of your system.
F.24Pump-related faults – the pump could have failed, it may have over run or there could be an issue with the airlock

Vaillant Ecomax Pro 828E

ErrorPossible Cause
F.00, .04, .05, .10, .14, .15All of these are NTC faults, and are best resolved by first changing all NTC to make diagnosis earlier.
F.21The pilot flame has failed.
F.22There is insufficient water in your system.
F.11A blockage in the appliance is preventing the system from flowing as it should.
F.12A blockage in the appliance is affecting the system’s pressure.
F.13The appliance is blocked because of a water deficiency.

Vaillant EcoTEC 65kW Error Codes

ErrorPossible Cause
S.OHeating issue, no heat demand
S.1Fan start-up error
S.2Pump flow error
S.3Heating mode error – ignition problem
S.4Heat mode – burner on error
S.6Heating mode – fan overrun error
S.7Heating mode – pump overrun error
S.8Heating remaining cut off for XX amount of time
S.31No heat demand summer operating mode
S.34Heating mode frost protection error
S.20Hot water requirement error
S.22Hot water handling pump flow error
S.24Hot water operation burner is on
S.85Service message quantity of circulation water

Vaillant EcoTEC Gas Boiler Error Codes

ErrorPossible Cause
D.0Heating part load error
D.1Water pump overrun – time for heat mode
D.2Max burner anti-cycling period at 20c flow temperature
D.3Hot water flow temperature reading
D.4Current temperature for warm stat sensor
D.5Set value of flow temperature or target value of return
D.7Warm start temperature target value
D.8External controls heat demand
D.9Flow target temperature from external analogue regulator terminal
D.10Status internal heating pump error
D,11Status external heating pump error
D.12Cylinder charging pump via accessory module
D.13Hot water circulation pump
D.15Pump speed actual value
D.22Hot water demand
D.23Summer/Winter function
D.24Not relevant
D.25Hot water activation via eBus control
D.30Control signal for both gas valves
D.33Fan speed target value
D.34Fan speed actual value
D.35Not relevant
D.40Flow temperature target value
D.41Return temperature actual value
D.44Digitised ionisation – potential error
D.47Outside temperature with weather compensator – Vaillant controller only
D.76Remaining burner anti-cycling time in min
D.90Digital regulator status
D.91DCF status with connected external probe
D.97Activation of the second diagnostic level
D.98Telephone a heating engineer
D.14Pump speed target value
D.17Heating flow return regulation
D.18Pump operating mode
D.20Maximum set value for target cylinder
D.26Additional relay control ecoTec
D.27Switching accessory relay 1
D.28Switching accessory relay 2
D.50Offset for minimum speed
D.51Offset for maximum speed
D.60Number of safety temperature cut offs
D.61Number of unsuccessful lockouts
D.64Average ignition times
D.65Maximum ignition time
D.67Remaining burner anti-cycling time
D.68Unsuccessful ignitions in the first attempt
D.69Unsuccessful ignition for the second time
D.70Set diverter valve position
D.71Maximum setting of heater control knob
D.72Pump overrun time after warm start
D.75Maximum charging time for a storage without own controller
D.77Limitation of cylinder charging in output in kW
D.78Limitation of cylinder charging temperature in celsius
D.80Operating hours heating
D.81Operating hours hot water generation
D.82Burner start up in heating mode
D.83Burner start up in hot water mode
D.84Maintenance indicator – number of hours until the next maintenance
D.93DSN appliance variant setting
D.96Factory setting

Vaillant EcoTEC Plus Gas Boiler Error Codes

ErrorPossible Cause
Error CodePossible Cause
P.00The heating circuit and hot water circuit are purged
P.01Maximum load test program error
P.02Minimum load test program
P.06Filling mode test program

Vaillant EcoTEC Plus Regular Gas Boiler Error Codes

Error CodePossible Cause
S.20Warnstar demand
S.21Fan running
S.22Pump running
S.23Ignition sequence
S.24Burner ignited
S.25Fan and water pump running
S.26Fan overrun
S.27Pump overrun
S.28Anti-cycling mode
S.30No heating demand from external controls
S.31Central heating thermostat knob turned off
S.32Heat exchanger antifreeze active as fan speed variation is too high
S.34Anti-frost mode is active
S.36Not heating demand form low voltage
S.41Water pressure greater than 2.9 bar
S.42Response from accessory module or defective condensate pump is blocking burner operation
S.53Appliance is within the waiting period of the block operation function due to water shortage
S.54Appliance is within the waiting period of the block operation due to water shortage
S.96Return sensor error
S.98Flow return sensor check is running demand is block
D.0Heating part load error
D.1Water pump overrun – time for heat mode
D.2Max burner anti-cycling period at 20c flow temperature
D.3Hot water flow temperature reading
D.4Current temperature for warm stat sensor
D.7Warm start temperature target value
D.8External controls heat demand
D.9Flow target temperature from external analogue regulator terminal
D.10Status internal heating pump error
D,11Status external heating pump error
D.12Cylinder charging pump via accessory module
D.13Hot water circulation pump
D.22Hot water demand
D.23Summer/Winter function
D.25Hot water activation via ebus control
D.30Control signal for both gas valves
D.33Fan speed target value
D.34Fan speed actual value
D.36Hot water flow sensor
D.40Flow temperature target value
D.41Return temperature actual value
D.44Digitised ionisation potential error
D.47Outside temperature with weather compensator – Vaillant controller only
D.76Remaining burner anti-cycling time in min
D.90Digital regulator status
D.91DCF status with connected external probe
D.97Activation of the second diagnostic level
D.17Heating glow return regulation
D.18Pump mode return
D.19Operating modes of the two speed heating pump
D.20Maximum set value for target cylinder
D.27Switching accessory relay 1
D.28Switching accessory relay 2
D.50Offset for minimum speed
D.51Offset for maximum speed
D.58Activation of solar reheating
D.60Number of safety temperature cut off
D.61Number of unsuccessful lockouts
D.64Average ignition times
D.65Maximum ignition time
D.68Unsuccessful ignitions in the first attempt
D.69Unsuccessful ignition for the second time
D.70Set diverter valve position
D.71Maximum setting of heater control knob
D.72Pump overrun time after warm start
D.73Off set for warm start target value
D.75Maximum charging time for a storage without own controller
D.77Limitation of cylinder charging in output in kW
D.78Limitation of cylinder charging temperature in c
D.80Operating hours heating
D.81Operating hours hot water generation
D.82Burner start up in heating mode
D.83Burner start up in hot water mode
D.84Maintenance indicator – number of hours until the next maintenance
D.93DSN appliance variant setting
D.96Factory setting

Vaillant EcoTEC Pro/EcoTEC Plus Error Codes

ErrorPossible Cause
F.72Flow return NTC error – temperature difference too great
F.73Water pressure sensor signal in the wrong range, it is too low
F.74Water pressure sensor signal outside correct range, the sensor signal is too high
F.75Error with pressure – no pressure change detection when starting the pump
F.76Overheating protection on – primary heat exchanger has responded
F.77Flue non return flap condensate pump error
F.78Interruption to DHW outlet sensor at external controller
F.83Flow and or return temperature sensor error
F.84Error with flow/return temperature sensor temperature changing error
F.85Error with flow and return temperature, sensor incorrectly fitted
CONNECTIONNo communication with the PCB

Vaillant Error Codes F28 and F29

If your Vaillant boiler is showing either error code F28 or F29, then the condensate pipe has frozen and you will need to thaw it. This issue can occur during winter, as the pipe runs outside, but you can resolve it fairly easily. You can simply thaw the pipe, without the need to call out an engineer.

Vaillant Error Codes F28 and F29

ErrorPossible CauseMeaning
F.00NTC FaultsThis means that your Flow NTC (Negative Temperature Coefficient Thermistor) cable is either defective or broken and needs to be replaced
F.01NTC FaultsThe Flow NTC (Negative Temperature Coefficient Thermistor) cable is either defective or broken and needs to be replaced
F.10NTC Faults
F.11NTC Faults
F.13NTC Faults
F.20Boiler has exceeded the maximum temperature and needs to cool down
F.22Dry fire / Low water in system / OverheatThis means that there’s either no water in your system, you have a defective pump or the pump lead is defective
F.24Low water / Pump Failure / BlockagePump could be obstructed, running at low capacity, could be air trapped or the pressure might be too low.
F.28Either insufficient gas in the system, a defective electrode, ignition lead or electronic ignitor
F.29Flame extinguishedFlame or pilot light has gone out – check flue duct or gas supply.
F.60Gas valve control defectiveCable loom (connects gas valve) might have short circuited, gas valve assembly defective or electronic control system issue.
F.61Gas valve control defectiveCable loom (connects gas valve) might have short circuited, gas valve assembly defective or electronic control system issue.
F.62Defective gas valve closure mechanismBoiler has exceeded the maximum temperature and needs to cool down
F.63EEPROM (Electrically Erasable Programmable Read-Only Memory) errorElectronic fault.
F.64Electronic system or sensor faultFlow or back flow NTC has short circuited, or an electronic fault
F.65Electronic system temperature too highThis can happen because of an external heat source or an electrical fault
F.67Electronic fault in the flame system

Are you still none the wiser? Fear not, help is at hand. You can arrange a 15-minute video call with a qualified engineer at Herofix.com to diagnose your Vaillant boiler fault and discuss what to do about it.